Mechatronic Thermometer DN63 Type A88

Mechatronic Thermometer DN63 Type A88

MECHATRONIC RIGID STEM THERMOMETER

  • PT100 and mechanical measuring in the same point
  • No measuring errors due to measurement in two different points
  • Ideal positioning of both sensors
  • Vibration proof due to liquid filling
  • Fewer assembly points
  • Food, beverages and pharma: better hygienic design
  • Tough environments: fewer leakage points

Title 1

Title 2

Title 3

Title 4

Title 5

Specifications

Case size
Type
DN63
A880101 Down
A880102 Rear
Case
Immersion probe
Standard length
Min. Insert length
AISI304
AISI316
L100
60 mm
Liquid filling Silicone oil
Connection Adjustable nipple or pocket, see datasheet 3-98, 3-99
Range: standard
Optional
Span between
0-160 °C
.
-40+250 °C
Accuracy
Mechanical
PT100
.
EN13190 Cl.1
DIN IEC 751 Cl.B
Electrical:
Connection
Element
.
M12x1 IEC 60947-5-2
PT100, 3-wire

Mechatronic Thermometer DN63 Type A88

A COMBINED INSTRUMENT

The mechatronic rigid stem thermometer combines the well known TEMPRESS rigid stem thermometer and an electronic temperature sensor (PT100) into one useful instrument.

Due to its construction, with the electronic sensor lead running through the thermometer stem into the bulb, it is possible to conduct both mechanical and an electronic measurement in the same point.

Where used

Carrying out the mechanical and electronic measurement gives a number of advantages. e.g. it eliminates the possibility of different readings due to measuring in 2 different points.
When measurements in tough environments where harsh chemicals and sour gasses are in use it eliminates the potential no. of leakage points. In sanitary applications it minimizes the no. of dead legs where dirt can assemble and pollute a sanitary system.
Further more the mechatronic thermometer is faster and cheaper to install due to the fact that it reduces the number of installation points in a large process system.

Standard articles

Click on the article to automatically insert into the contact form below

To view our standard articles please visit from a desktop

No items found.

Single contact

(1 contact point)

Avaliable contact types:

KN,KM,KE and KI

Contact Function : Break

1

Contact Function : Close

2

Contact Function : Shift

3

Contact Function Separate Circuits : Break

4

Contact Function Separate Circuits : Close

5

Double contact

(2 contact points)

Avaliable contact types:

KN,KM,KE and KI

Shift contact

(2 contact points switch function)

Avaliable contact types:

KN and KM

Double contact

(2 contact pointers seperate Circuits)

Avaliable contact types:

KN and KM

Triple contact

(3 contact pointers)

Avaliable contact types:

KN and KM

Triple contact

(3 contact pointers)

Avaliable contact types:

KN and KM