Capsule Gauge DN63 Type P1120

Capsule Gauge DN63 Type P1120

CAPSULE PRESSURE GAUGES

The TEMPRESS capsule gauge was developed as a supplement to TEMPRESS low pressure gauges. The Capsule gauge is for measuring air, other nonaggressive gasses, and vacuum within ranges 0-600m.BAR.

Title 1

Title 2

Title 3

Title 4

Title 5

Specifications

Case: Stainless Steel DIN 1.4301(AISI 304) with bayonet lockingfront
Front: Stainless Steel DIN 1.4301(AISI 304).
Glass face: Instrument glass.
Measuring system: Capsule measuring elementCuBe 2
Connection: Brass 1/2″ BSP bottom
connection 22 A/F dia. 63 mm1/4″ BSP, 14 A/F rear center.
Range:
Min.:
Max.:
DIN 16130.
-25/0 m.BAR.
0/600 m.BAR.
Accuracy: DIN 16130Class 1.6 (+1.6% of full scale deflection F.S.D.) at am-bient temperature +20 deg C

 

Ambient temperature changes result in an indication error of+/- 0.3%F.S.D. per 10 deg C.

Load:
Static:
Dynamic:
DIN 16005.
100% F.S.D
88% F.S.D.
Temperature DIN 16055 resistance Soft solder max. 60 deg C. standards.

Capsule Gauge DN63 Type P1120

Optional specifications:

Bezel (AISI 304) polished.

Clamp fixing.

Bezel black.

Bezel DIN 1.4301 (AISI 304).

Triangular bezel and fixing clamp.

Splashproof.

Measuring system over/underrange protected,

10 times range (>40 m.BAR)

Connecting thread in accordance with customer requirements.

Throttle screw.

Zero-adjustment.

Special Scales.

Logo.

Dual scale psi/m.BAR/Pa.

Nylon capillary for remote indication.

Adjustable pointer.

Externally adjustable memory pointer.

Built-in Contact Systems (Ø100/160 only).

Built-in Opto-Electronic Transmitter (Ø100/160 only).

Capsule Gauge Ø160 only on request.

Standard articles

Click on the article to automatically insert into the contact form below

To view our standard articles please visit from a desktop

No items found.

Single contact

(1 contact point)

Avaliable contact types:

KN,KM,KE and KI

Contact Function : Break

1

Contact Function : Close

2

Contact Function : Shift

3

Contact Function Separate Circuits : Break

4

Contact Function Separate Circuits : Close

5

Double contact

(2 contact points)

Avaliable contact types:

KN,KM,KE and KI

Shift contact

(2 contact points switch function)

Avaliable contact types:

KN and KM

Double contact

(2 contact pointers seperate Circuits)

Avaliable contact types:

KN and KM

Triple contact

(3 contact pointers)

Avaliable contact types:

KN and KM

Triple contact

(3 contact pointers)

Avaliable contact types:

KN and KM

Do you need assistance?

Vi står altid til rådighed til at hjælpe dig, uanset hvilke spørgsmål du måtte have. Tøv ikke med at kontakte os gennem kontaktformularen, eller find din kontaktperson her

Thank you for reaching out. We'll be in touch as soon as possible.
Oops! Something went wrong while submitting the form.