Pressure Transmitter P1237 – Digital, programmable, down scalable
Description:
The wide application field of pressure transducers is guaranteed by the high accuracy and the rugged design.
The stainless steel membrane is completely vacuumsealed, extremely burst resistant and applicable for all standard media for hydraulics, pneumatics, environmental engineering, process technology, semiconductor technology and automotive engineering. Thus the use for standard applications of mobile hydraulics and other application areas is covered.
Due to the manufacturing process all pressure transducers are being individually pressure- and temperaturetested.
The production occurs due to the requirements of DIN EN ISO 9001:2008.
Construction:
The compensation and adjustment is carried out electronically. Thus the pressure transmitters have a very low total error and a very good long-term stability. The measuring cell is characterised by its high long-term resistance and long-term stability.
With the precision of modern electronics, the measured data can be captured accurately. Even the programming of the pressure transducers by the user can be realised on a service tool or PC programming kit. The graduation of the measuring range and the zero point can be set up through the digital interface. Furthermore sensor data can be readout from the device. By using permanent magnets the adjustment of the zero point can easily and securely be done at any time.
Special Features:
Accuracy
- < 0.35% BFSL
Temperture drift in th compensated range:
0/70 °C < 1,5 % FS/10 K
Robust construction
- Wetted parts of stainless steel
- Protection category IP 65
Programmable by PC programming kit or service tool
- Zero point (offset)
- Down scalable 4:1
- Zoom and SPAN
- Characteristics / Output options
(inverse, square rooted, special forms)
Straightforward zero correction by using a magnet
Output signals
- 4 … 20 mA
- 0 … 10 V
- 0 … 5V
- Digital
Process connections
- Standard to chart
- Others on request
Diaphragm seals available
- According to specific datasheets
Figure similar depending on model


Technical Data | Typ P1237 |
---|---|
Standard pressure ranges * ) ( bar) | -1_____ 0,1_____ 0,3_____ 0,6_____ 1_____ 1,6_____ 2,5_____ 4_____ 6_____ 10_____ 16_____ 25_____ 40_____ 60_____ 100 _____ 160_____ 250_____ 400_____ 600_____ 1000_____ 1600_____ 2000 |
Overload ( bar) *) | Max. 1.5 times / 1.2 times – depending on pressure range |
Burst pressure ( bar) *) | 2 times / 1.5 times – depending on pressure range |
Kind of pressure | Vacuum, gauge pressure, absolute pressure on request |
Wetted parts | Stainless steel |
Weight ( g) | Approx.. 200 g |
Supply voltage ( VDC ) | 10…30 V at 4..20 mA / 14…30 V at 0…10V |
Output signals and max. load | 4…20mA, 2 wire Ra<=(Ub-10V)/20mA
0...5 V, 3 wire Ra>5 ohm 0…10V, 3 wire Ra>10 ohm Digital optional |
Adjustability of zero
| Straightforward zero correction by using a magnet or via interface and PC programming kit |
Adjustability of span | 1:4 with pressure ranges (FS) via interface and software |
Adjustability time constant | via interface and software |
Sample rate | ˃250 Hz |
Response time (10 … 90 %) | ≤ 10 ms |
Accuracy **) | ≤ 0,35 % BFSL (Including non-linearity, zero point and full scale error, hysteresis, non-linearity and repeatability) Compensation measurement and adjustment for vertical mounting position |
Non-linearity *** ) | % FS ≤ 0,25 |
Repeatability | % FS ≤ 0,1 |
Long-term stability | % FS ≤ 0,1 1-year stability at reference conditions |
Permissible temperatures | |
Media temperature | -20….+ 80 ( 120) °C |
Ambient temperature | Ambient temperature -20….+ 80°C |
Storage temperature | Storage temperature -20….+ 80°C |
Compensated temp. range | -20…+ 80 °C |
Temperature coefficient zero | % FS ≤ 0,1 / 10K |
Temperature coefficient FS | % FS ≤ 0,1 / 10K |
Coefficient FS % FS ≤ 0,1 / 10K CE-conformity | |
Pressure equipment directive | 97/23/EG |
EMC directive | 2004/1 08 EG |
Shock resistance | g 100 to IEC 60068-2-27 mechanical |
Vibration resistance | g 20 to IEC 60068-2-6 resonance |
Wiring protection | |
Over voltage | 32 VDC |
Short-circuit strength | Out+ / UB- (for 1s) |
Reverse polarity | UB+ / UB- |
* ) Others on request
** ) Special custom design with optional better accuracy on request
***) integral linearity error (FS = Full Scale, BFSL = Best Fit Straight Line)
Connections Diagram
2-wire current (4…20mA)*
3- wire voltage (0…10V , 0…5V)*

M12x1 (Binder series S763)
2 wire : 1 + , 2; 3 wire : 1+, 2 Gnd , 3+ out/ signal*
Cable : 2 wire : red + , black; 3 wire : red + , black -, white out,*
* ) Others on request
Standard in stock
Following ranges are availble from Tempress stock: 0-1/0-1,6/0-2,5/0-4/0-6/0-10/0-16/0-25/0-40/0-60/0-100/0-160 Bar.
The stock items are all with media contacted parts in stainless steel, G1/4B process connection and electrical connection MVS/Form A DIN EN 175301-803.
Diaphragm seal: please specify according to datasheets.
Zero correction
The zero can be set easily with a magnet within ± 10 % of the nominal range.
To correct the zero point, hold a permanent magnet– a pin board magnet, for example – at the position marked on the pressure transmitter (i.e. a letter in a circle) for ½ to 2 ½ minutes after the power has been switched on. To correct the zero, atmospheric pressure is applied. Offsets for previously set values for initial and ultimate pressures will be corrected automatically by the device. A magnetic field applied outside of this set again.

Parameterization
Parameterization of measuring range (1:4), zoom, span and adjustment of characteristic diagram are possible with service tool or PC adapter and software. Programmable devices are only available with Electrical connection by Binder M12 (Binder series S763) or by cable.
The service tool or the PCF software are available accessory.
Service
The sensors are free of maintenance.
Note
We compiled this operating instruction carefully. Nevertheless, it was not possible to take all possibilities of application into account. If this data sheet should lack the solution of your special task, please don’t hesitate to contact us.
Safety information
During installation, putting into service and operation of the pressure sensors, it is necessary to observe the relevant safety regulations that are in force in the country of the user (as for example, DIN VDE 0100). Errors excepted; subject to alterations in the sense of technical improvement.