Pressure gauge external autoclavable – Type A47

Sheet No.: 1-640 GB

Pressure gauge external autoclavable

  • Autoclavable in oven
  • EN10204-3.1.certificate on wetted parts
  • Surface roughness certificate on wetted parts
  • All parts of gauge in AISI316
  • Handling instruction for each instrument
  • No loss of accuracy
  • FDA and ph Eur2000 add. Approved transmission liquid

Application

The Tempress External Autoclavable pressure gauge is a special designed gauge which is suitable for

  • Mobile tanks in pharmaceutical production plants
  • Hospital equipment
  • Bio technical installations

where external autoclaving of the equipment is required due to hygienic requirements.

The unique design ensures that the pressure gauge can resist both the heat and the moisture in an autoclave process and continue working perfectly after the process without loss of accuracy.

Specifications
Pressure Gauge:
Option
DN 100: A4703
DN 63
Case material:
Glass face:
Bezel:
AISI 316
Tempered safety glass
AISI 316
Liquid fillingNone, dry house
Connection:Bottom
Measuring system::AISI 316
Range:2.5 / 4 / 5 / 7 / 11 & 20 bar
Accuracy:Cl. 1.6 (±1.6%FS)
Temperature:
Media
Ambient
Options:
0° C + 140° C
0° C + 140° C

Media and amb. Temp. up to 200° C for dry sterilisation (Ask Tempress)

Autoclaving temp.:Max. 140°C
ClampDN38 DS/ISO2852
AISI316L, Diaphragm AISI316L
Transmission liquidFDA approved
Meets ph Eur2000 add.
Requirements
CertificateEN10204 – 3.1